Membrane Scaling and Fouling Mitigation Measures - Antiscalant Testing
Investigators: Markus Busch, Yulia Galperin and Alexander Drak
Supervisors: Prof. David Hasson and Prof. Raphael Semiat
Rabin Desalination Laboratory, WRI, Faculty of Chemical Eng., Technion, Israel
Project abstract:
The objectives of this project are to develop and test laboratory techniques for
characterizing the scaling propensity of feed waters and for assessing the relative
effectiveness of various antiscalants. Three different scaling characterization
techniques are being developed: a batch recycle technique, a once through technique
and an intermittent recycle technique.
Research funded by EC Project no. JOE3-CT97-0053
Publications:
Hasson, D., Semiat, R., Bramson, D., Busch, M. and Limoni-Relis, B.,
"Suppression of CaCO3 Scale Deposition By Anti-Scalants", Desalination, 118 , (1998) pp. 285-296.
|
 
|